ÄKTA protein-purification systems are run by Cytiva UNICORN. UNICORN 3–5 save .res result files; UNICORN 6 and 7 keep results in a database and export them as .zip files. OpenReadout reads both and returns the curves, the logbook, fraction and injection marks, and the method; from 6/7 exports also UNICORN’s peak tables.

Derived from hex dumps and XML of public files (ÄKTAprime, Ettan LC, ÄKTA pure and ÄKTA avant), allotropy’s cytiva_unicorn reader (MIT) read as prior art, and the public MS-NRBF specification; PyCORN (GPL-2.0) and allotropy are run as black boxes for ground truth. Provenance: docs/provenance/cytiva-unicorn.md. Crate: openreadout-fplc.

format id files reads confidence
cytiva-unicorn-res .res (UNICORN 3-5 result files; ÄKTAprime, Ettan LC; header text UNICORN 3.10) curves, logbook, fraction and injection marks, method text low (evidence rubric, docs/assurance.md)
cytiva-unicorn-zip .zip written by UNICORN 6/7 Export result curves, logbook, fraction and injection marks, UNICORN’s peak tables, system, instrument, column, method medium (evidence rubric, docs/assurance.md)

Not read: the UNICORN 6/7 database itself and its backups, .result/.bak files, method files, report PDFs. A zip that is not a result export (no Result.xml and Chrom.<n>.Xml) is refused with exit 6 and a hint.

The model (both variants)

A UNICORN result is one chromatography run: curves recorded against time (UV absorbance at up to three wavelengths, conductivity, pH, pressures, temperatures, the %B the pumps deliver, flows), event lists (the logbook of method instructions, fraction marks, injection marks) and, in UNICORN 6/7 exports, peak tables the software integrated.

Traces: one per curve

  • name: the curve name as the file gives it (UV 1_280, Cond, % Cond, Conc B, System pressure, UV1_215nm, SAPA_215nm). With several chromatograms in one export the names start with Chrom.<n>: .
  • channel 0: the values, named by the curve kind (below), in the file’s unit (mAU, mS/cm, %, MPa, °C, ml/min, cm/h, CV/h, cm; pH has none). Channel 1 volume: the retention volume of each sample in ml, counted from the method start, as stored.
  • sample_rate_hz and start_s: the curve is sampled at a fixed interval from the method start; sample i is at start_s + i / sample_rate_hz seconds. trace statistics give both the time of the maximum (argmax_time_s) and its retention volume (argmax_axis_value, ml).
  • extra.axis = {quantity: retention_volume, unit: ml, irregular: true, channel: 1}: the volume is the curve’s abscissa (UNICORN plots against volume). trace --x-range A:B selects by volume. analyze chromatogram and analyze peaks work on the time base (minutes).

Trace extra (our vocabulary):

key meaning
kind uv, conductivity, conductivity_percent, concentration_b, ph, pressure, temperature, flow, other (from the unit, the name and the UNICORN 7 curve type)
wavelength_nm UV wavelength from the curve name (UV 1_280 → 280; a channel named …_0 is a switched-off monitor channel and has none)
original true for curves the instrument recorded, false for curves the software evaluated afterwards (smoothed, baseline-corrected, cut)
interval_min, start_min sampling interval and time of sample 0 after the method start, minutes
injection_volume_ml the volume of the last injection mark: UNICORN draws retention volumes from it (subtract it to match UNICORN’s axis)
curve_type UNICORN 7’s own curve type (UV, Conduction, pH, Pressure, Temperature, Other)
curve_number UNICORN 7’s curve number (peak tables refer to it)
isochrone time (sampled in time) or volume (an evaluated curve on a volume grid: it has volumes but no times)
volume_step_ml, volume_start_ml the volume grid of an evaluated curve
column_volume_ml the column volume the export records with the curve
uv_path_length, uv_nominal_path_length, uv_normalized_to_nominal_path UV flow-cell path length (cm) and whether values are normalized to the nominal path
display_decimals decimals UNICORN displays
method_start the method start with its UTC offset (UNICORN 7)
member the export member that holds the points
block, channel_label, time_axis_label, volume_resolution_ml, time_offset_ms .res: the block name, its column labels, the volume resolution (the stored integer’s factor) and a sub-sample start offset (see below)

Tables

Event lists come first, one table each, then the peak tables.

  • logbook, fractions, injections (and any other event list by its lower-case name): columns time (min), volume (ml) and the text as a category code: text (the logbook line), fraction (the tube or well label, Waste), injection (the injection number or text). Table extra.kind = events.
  • Vendor peak tables (UNICORN 6/7, named as UNICORN names them, e.g. UV 1_280@01,PEAK (1)): one row per peak, UNICORN’s integration as stored: retention (the maximum), start, end, height, area, percent_of_total_area, percent_of_total_peak_area, width, width_at_half_height, resolution, asymmetry, sigma, start_endpoint_height, end_endpoint_height, average_conductivity, and name when peaks are named. Retentions are in ml (or min when the table’s basis is time) from the injection the table is zeroed at (extra.zero_at_injection); heights in the curve’s unit, areas in unit·ml. Table extra: kind = vendor_peaks, trace (our curve), retention_basis, curve_number, detected_peaks, total_peak_area, total_area_evaluated_peaks, ratio_peak_area_total_area, max_peaks, zero_at_injection, column_volume_ml, algorithm, technique, created, height_reference (baseline or zero), baseline_curve_number and baseline_trace (the evaluated baseline curve the table is measured above, when it names one).
  • What UNICORN’s peak values mean (validated on the exports of docs/provenance/cytiva-unicorn.md): height = curve − baseline at retention; area = the trapezoid integral of curve − baseline over retention volume from start to end (ends interpolated); start_endpoint_height and end_endpoint_height = curve − baseline at the limits; width = end − start. The baseline is the table’s baseline_trace (UNICORN’s …BASEM evaluated curve on a volume grid); a table without one measures from zero, so its heights equal the curve. A drifting UV signal therefore gives heights below the curve maximum; subtract the baseline trace to reproduce them.

Experiment facts

instrument: vendor Cytiva (ÄKTA), software UNICORN, the model (.res: the system named in the method dump or strategy notes, e.g. AKTAprime, EttanLC; UNICORN 7: the instrument configuration, e.g. AKTA pure 25), the UNICORN version (UNICORN 7). method: name (the logbook’s Method Run … Method: <name>, the method file, or the method description), technique (size-exclusion CHMO:0001013, affinity CHMO:0001006 or ion-exchange CHMO:0001014 when the method or column says so, else liquid chromatography CHMO:0001004) and parameters: column, column_volume (mL), column_article_number, column_bed_height (cm), flow_rate (mL/min), fraction_volume (mL), uv_wavelength_1…3 (nm), technique (UNICORN’s own word), run_duration (min), firmware. acquisition: operator (.res: the header user; UNICORN 7: the result’s creator), start (UNICORN 7: the method start with its offset; .res: derived, see below), end (.res), duration. sample.id when the method has a Sample_ID variable with a value.

.res (UNICORN 3-5)

Little-endian. Header: 11 47 11 47; u32 at 8 the directory offset; u32 at 16 the file size (a mismatch is reported as truncation); text at 0x18 (UNICORN 3.10 in both files: a layout version, not the software version, reported as format_version); u32 Unix times at 0x68 and 0x6c; the user name at 0x76.

Directory: 344-byte entries until an empty name: bytes 0-5 a type word, 6-301 the NUL-terminated name, then u32 data size, u32 allocated size, u32 data offset, u32 header size (240 curves, 552 event lists, 0 others). Curve names are <run name>:<run number>_<curve>; an evaluated curve’s name starts with = and its type word has 03 where recorded curves have 01.

Curve and event blocks start with u16 6, u16 stored columns, u16 1, then 78-byte column descriptors: u16 78, u16 flags (0x8001 time, 0x8002 volume, 0x4001/0x4000 value), a 40-byte label, a 16-byte unit, u16 storage (0x0104 int32, 0x0308 float64, 0x044c 76-byte text), float64 factor, float64 second value.

  • Curves: three descriptors; (int32 volume, int32 value) pairs follow the header; physical = stored × factor (a factor of 1/k divides by k so 15328 × 0.001 is 15.328). The time column is not stored: its factor is the sampling interval in minutes and sample i is at i × interval. Its second value, when not 0, is read as a start offset in milliseconds (always below one sampling interval in the files seen; extra.time_offset_ms; an assumption, see provenance).
  • Event lists: 180-byte records: float64 time (min), float64 volume (ml), two 76-byte texts (joined), float64 value, int32 flags.
  • Text blocks (CreationNotes, Methods, MethodStrategyNotes, ResultStrategyNotes, Techniques, METHODINFO, Method Signatures) are kept in the vendor tree; binary blocks are listed by info --view structure.
  • Times: acquisition.ended_at is the header time at 0x6c (UTC; it matched the run end in both files); started_at is that time minus the longest curve’s duration (the logbook’s Method Run text is local time without a zone and is kept in the vendor tree as method_run); the time at 0x68 is kept as header_time_0x68 (it matched the start in one file and not in the other).

UNICORN 6/7 result export (.zip)

A zip whose members are XML documents and nested zips (members may sit in a folder or carry Copy of prefixes and .zip suffixes when a user re-packed the export: names are matched on their base name without them):

  • Result.xml: result name, system name, creator and times, run information (base64 text: used columns, instrument server version, run start), and the method’s variable values (ResultSearchCriteria keyword/value/unit triples; all in the vendor tree, the common ones as method parameters).
  • Chrom.<n>.Xml: per curve its name, CurveDataType, AmplitudeUnit, IsoChroneType, DistanceBetweenPoints and DistanceToStartPoint (minutes for time curves, ml for volume-grid curves), MethodStartTime and its UTC offset, IsOriginalData, ColumnVolume, CurveUVInfo, and the member holding the points; event curves (Fraction, Injection, Logbook, …) with EventTime (min), EventVolume (ml), EventText; peak tables.
  • Nested zips (SystemData, InstrumentConfigurationData, ColumnTypeData, MethodData, MethodDocumentationData, StrategyData, …) hold XmlDataType (System.String) and Xml: a .NET binary-serialized string (MS-NRBF: a 17-byte serialization header, a string record with a 7-bit length prefix, a message end). A damaged or non-serialized metadata document is a warning, never fatal.
  • Curve points (Chrom.<n>_<curve>_True): a nested zip (ZIP64 local headers, padded with zeros after the end record) with CoordinateData.Volumes and CoordinateData.Amplitudes, each an MS-NRBF array of 32-bit floats (record 15, primitive type 11) and a …DataType member (System.Single[]). The declared array length must fill the member exactly; a member cut short or holding bare floats is refused (the curve is left out, check reports it). An evaluated curve on a volume grid may store no volumes: they are volume_start_ml + i × volume_step_ml.
  • Time of sample i = DistanceToStartPoint + i × DistanceBetweenPoints (validated against every event of six exports, see provenance). A curve with a zero or missing interval keeps its volumes and has no times (a warning).

Manifest.xml lists members with CRC codes that do not match the nested zips; they are not used. Every member read is checked against its zip CRC-32.

Validation

cargo test -p openreadout-corpus-tests --features corpus (tests/fplc_oracle/mod.rs): every curve PyCORN returns matches ours at 128 sampled positions (exactly for UNICORN 7 floats; within 1e-9 for .res), allotropy’s data cubes agree (it converts conductivity to S/m), fraction and injection marks match, the 22 vendor peaks of the two exports with peak tables (one measured from zero, one above a baseline curve) have their height (curve − baseline at the retention) and area (∫ curve − baseline) within 0.5 % of UNICORN’s and their width equal to end − start, and damaged curve members are refused. PyCORN and allotropy both read UNICORN 7 floats from byte 47 to 48 bytes before a member’s end, so they drop the first five and last eleven samples of every curve; the record layout accounts for every byte, and the event (time, volume) pairs fit our sample indexing, not theirs. PyCORN applies fixed scales to .res pH and pressure (÷10, ÷100) where the ÄKTAprime file declares 0.01 and 0.001; its method dump’s 300 kPa pressure limit, which PyCORN’s values would exceed for the whole run, shows the declared factor is right.

Vocabulary (public API of openreadout-fplc)

identifier meaning
UnicornResReader reader of UNICORN 3-5 .res result files
UnicornZipReader reader of UNICORN 6/7 result exports (.zip)
UNICORN_RES_FORMAT_ID cytiva-unicorn-res
UNICORN_ZIP_FORMAT_ID cytiva-unicorn-zip
FplcDataset the dataset both readers return